12 Interview Questions & Answers for HVAC Engineers

Get prepared for the Job

Q1. What is the Unit of Heat?

The unit of heat is joule (J) in the International System of Units (SI). However, other units such as calorie (cal) and British thermal unit (BTU) are also commonly used to express quantities of heat in non-scientific contexts.

Q2. What is BTU?

BTU stands for British Thermal Unit. It is a unit of measurement commonly used in the United States and other countries to express quantities of heat. One BTU is defined as the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit at sea level. The BTU is typically used to describe the heating or cooling capacity of appliances such as air conditioners or furnaces.

Q3. What are the Types of Heat?

There are different ways to classify the types of heat, depending on the context and the level of detail required. Here are a few possible classifications:

Sensible heat vs. latent heat: Sensible heat is the heat that can be sensed or measured by a thermometer, and it reflects changes in the temperature of a substance without changing its state (for example, melting or boiling). Latent heat, on the other hand, is the heat absorbed or released during a phase change, such as melting or vaporization, without a change in temperature.

Conduction vs. convection vs. radiation: These are three modes of heat transfer. Conduction occurs when heat flows through a material from a region of higher temperature to a region of lower temperature, without any bulk motion of the material. Convection involves the transfer of heat by the movement of fluids (such as air or water) due to differences in density caused by temperature variations. Radiation refers to the emission of electromagnetic waves (such as light or infrared radiation) by a hot object, which can be absorbed by another object and converted into heat.

Internal vs. external heat: Internal heat refers to the heat generated within a system, such as the Earth's core or a power plant, while external heat refers to the heat exchanged between a system and its surroundings, such as the absorption of sunlight by the Earth's surface.

These are just a few examples, and there are many other ways to categorize heat depending on the specific application or field of study.

Q3. What are the Types of Heat?

These are just a few examples, and there are many other ways to categorize heat depending on the specific application or field of study.

Q4. What is the definition of 1 Ton Refrigerant?

The definition of 1 ton of refrigeration (TR) refers to the cooling capacity of an air conditioning or refrigeration system. One ton of refrigeration is equal to the amount of heat required to melt one ton (2,000 pounds) of ice in 24 hours, which is equivalent to 12,000 BTU per hour or 3.516 kilowatts of power.

In other words, a 1-ton refrigeration system can remove 12,000 BTUs of heat per hour from a space and maintain a temperature of about 20 degrees Celsius. The exact definition and use of the term "ton of refrigeration" may vary depending on the region and industry, but it is a standard unit for rating the cooling capacity of HVAC (heating, ventilation, and air conditioning) systems.

Q5. What is the most common units of measurement for the volume of air in HVAC?

The most common units of measurement for the volume of air in HVAC (heating, ventilation, and air conditioning) systems are cubic feet per minute (CFM), liters per second (L/s), and cubic meters per hour (m3/h).

The equation to calculate the volume flow rate of air in a duct or system is:

Q = A × V

where Q is the volume flow rate, A is the cross-sectional area of the duct or opening, and V is the velocity of the air.

To convert between different units of measurement, you can use the following conversion factors:

1 CFM ≈ 0.4719 L/s
1 CFM ≈ 1.699 m3/h
1 L/s ≈ 2.1189 CFM
1 L/s ≈ 3.6 m3/h
1 m3/h ≈ 0.5886 CFM
1 m3/h ≈ 0.2778 L/s
For example, if you know that the velocity of air in a duct is 10 meters per second and the cross-sectional area of the duct is 2 square meters, you can calculate the volume flow rate as follows:

Q = A × V = 2 m2 × 10 m/s = 20 m3/s

To convert this value to CFM, you would multiply it by 2118.9:

20 m3/s × 2118.9 CFM/(m3/s) = 42,378 CFM

Q6. What is ASHRAE stands for?

ASHRAE stands for the American Society of Heating, Refrigerating and Air-Conditioning Engineers. It is a professional organization that focuses on advancing heating, ventilation, air conditioning and refrigeration (HVAC&R) technology to serve humanity and promote sustainability. ASHRAE provides industry standards, guidelines, research, education, and certification programs for HVAC&R professionals worldwide. The organization was founded in 1894 and is headquartered in Atlanta, Georgia.

Q7. What is the comfort room temperature that need to be maintained in rooms?

The ideal room temperature for comfort may vary depending on personal preference, clothing, activity level, and other factors. However, in general, the recommended comfort temperature range for occupied spaces is between 68-76°F (20-24°C) during winter months and between 75-80°F (24-27°C) during summer months. These are just general guidelines, and the specific recommended temperature may vary depending on local climate conditions and the type of building or space being considered. It's important to note that maintaining comfortable indoor temperatures also depends on proper insulation, ventilation, and air circulation in the building.

Q8. How much is 1 TR in BTU/hr and KW?

1 TR (ton of refrigeration) is equal to 12,000 BTU/hr (British Thermal Units per hour).

To convert TR to kW (kilowatts), you can use the following formula:

1 TR = 3.516 kW

So, 1 TR is equal to approximately 3.516 kilowatts.

Q9. What is the heat transfer coefficient?

The heat transfer coefficient, also known as the thermal transfer coefficient, is a measure of how fast heat energy moves through a material or system. It represents the amount of heat that can be transferred from one surface to another per unit of time and per unit of area, for a given temperature difference between the two surfaces.

The value of the heat transfer coefficient depends on various factors such as the nature of the materials involved, the geometry of the system, the fluid flow rate (in case of convective heat transfer), and the temperature difference driving the heat transfer. Therefore, the value of the heat transfer coefficient may vary widely depending on the specific circumstances of the heat transfer process.

Typical values of the heat transfer coefficient range from very low values of a few W/m²K for solid materials with poor thermal conductivity, to high values of several thousand W/m²K for convective heat transfer in fluids under high flow rates and turbulence conditions.

Q10. What is the Thermal Conductivity?

 Thermal conductivity is a measure of how well a material conducts or transfers heat. It represents the ability of a material to allow heat energy to flow through it by conduction.

Thermal conductivity is measured in units of watts per meter per Kelvin (W/mK). It indicates how many watts of heat energy can be transferred through one meter of material thickness, for a temperature difference of one degree Kelvin (or Celsius) across the material.

Materials with high thermal conductivity are good conductors of heat and can transfer heat quickly from one point to another. Examples of such materials include metals like copper, aluminum, and silver. Materials with low thermal conductivity are poor conductors of heat and impede the flow of heat energy through them. Examples of low thermal conductivity materials include insulators like wood, plastics, and ceramics.

The value of thermal conductivity depends on various factors such as the nature of the material, its temperature, pressure, and density, and the presence of any impurities or voids within the material. Knowing the thermal conductivity of a material is important in designing and selecting materials for applications where heat transfer is critical, such as in building insulation, electronic devices, automotive engines, and refrigeration systems.

Q11. What is aspect ratio in terms of Duct Sizing?

 
In the context of duct design, aspect ratio refers to the proportional relationship between the width and height (or diameter) of a rectangular or circular duct.

For rectangular ducts, the aspect ratio is calculated by dividing the width of the duct by its height. For example, if a rectangular duct has a width of 20 inches and a height of 10 inches, its aspect ratio would be 2:1.

For circular ducts, the aspect ratio is calculated by dividing the diameter of the duct by its height. However, in practice, aspect ratio is not commonly used for circular ducts, as they are usually designed to have a constant diameter along their length.

Aspect ratio is an important consideration in duct design, as it can affect the performance and efficiency of the HVAC system. Ducts with high aspect ratios (i.e. long and narrow rectangular ducts) may experience higher friction losses and pressure drops, which can reduce the airflow rate and increase energy consumption. Therefore, it is often recommended to design duct systems with low aspect ratios (i.e. short and wide rectangular ducts), where possible, to minimize these issues.

The acceptable range of aspect ratio in duct sizing depends on various factors such as the type of duct system, the airflow rate, and the design requirements. In general, however, it is recommended to keep the aspect ratio of rectangular ducts below 3:1 to minimize friction losses and pressure drops.

For example, the ASHRAE Handbook - Fundamentals recommends that the aspect ratio of rectangular ducts be limited to a maximum of 2:1 for sheet metal ducts and 3:1 for flexible ducts. The SMACNA (Sheet Metal and Air Conditioning Contractors' National Association) also provides guidelines for designing rectangular ducts with aspect ratios between 1:1 and 3:1, depending on the airflow rate, the duct material, and other factors.

It's important to note that circular ducts are usually designed to have a constant diameter along their length, so aspect ratio is not commonly used for these types of ducts.

In practice, the final aspect ratio of a duct system will depend on many factors, including the available space, the practicality of installation, and the desired airflow rate and pressure drop. A qualified HVAC engineer or designer can help to determine the appropriate duct size and aspect ratio for a given application.

Q12. What is the Collar Length?


In HVAC ductwork, a collar length refers to the length of the metal sleeve or flange at the end of a duct that is used to connect it to another duct or piece of equipment. The collar serves as a transition piece between the duct and the other component, such as an air handler, grille, or diffuser.

The collar length may vary depending on the specific application and requirements of the system. Generally, the collar length should be sufficient to provide a secure and airtight connection between the ducts or equipment while allowing for easy installation and maintenance.

In rectangular ductwork, the collar length is usually equal to the height of the duct plus any additional length needed for the flange or lip. For example, if a rectangular duct has a height of 12 inches and a flange with a depth of 1 inch, the collar length would be 13 inches.

In round ductwork, the collar length is typically equal to the diameter of the duct plus any additional length needed for the flange or lip. For example, if a round duct has a diameter of 10 inches and a flange with a depth of 1 inch, the collar length would be 11 inches.

12 Interview Questions & Answers for HVAC Engineers
Administrator December 28, 2023
Share this post
Tags
Archive
Sign in to leave a comment

What is NCR ?
Non-Conformance Reports